defmodule RtuMaster do
use ExUnit.Case
@moduledoc """
These tests only runs if 'tty0tty' is installed in the host computer.
"""
test "Master test for fc => [1, 2, 3, 4, 5, 6, 15, 16]" do
RingLogger.attach()
{:ok, m_pid} = Modbux.Rtu.Master.start_link(tty: "tnt0")
model = %{
80 => %{
{:c, 1} => 1,
{:c, 2} => 0,
{:i, 1} => 1,
{:i, 2} => 1,
{:ir, 1} => 0,
{:ir, 2} => 1,
{:hr, 1} => 102,
{:hr, 2} => 103
}
}
{:ok, s_pid} = Modbux.Rtu.Slave.start_link(tty: "tnt1", model: model, active: true)
assert model == Modbux.Rtu.Slave.get_db(s_pid)
# Master Requests.
# Read Coil Status (FC=01)
resp = Modbux.Rtu.Master.request(m_pid, {:rc, 80, 1, 1})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:rc, 80, 1, 1}}}
# master
assert resp == {:ok, [1]}
# Read Input Status (FC=02)
resp = Modbux.Rtu.Master.request(m_pid, {:ri, 80, 1, 1})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:ri, 80, 1, 1}}}
# master
assert resp == {:ok, [1]}
# Read Holding Registers (FC=03)
resp = Modbux.Rtu.Master.request(m_pid, {:rhr, 80, 1, 2})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:rhr, 80, 1, 2}}}
# master
assert resp == {:ok, [102, 103]}
# # Read Input Registers (FC=04)
resp = Modbux.Rtu.Master.request(m_pid, {:rir, 80, 1, 1})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:rir, 80, 1, 1}}}
# master
assert resp == {:ok, [0]}
# Force Single Coil (FC=05)
resp = Modbux.Rtu.Master.request(m_pid, {:fc, 80, 1, 0})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:fc, 80, 1, 0}}}
# master
assert resp == :ok
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:c, 1}] == 0
# backward
resp = Modbux.Rtu.Master.request(m_pid, {:fc, 80, 1, 1})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:fc, 80, 1, 1}}}
# master
assert resp == :ok
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:c, 1}] == 1
# Preset Single Register (FC=06)
resp = Modbux.Rtu.Master.request(m_pid, {:phr, 80, 1, 10})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:phr, 80, 1, 10}}}
# master
assert resp == :ok
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:hr, 1}] == 10
# backward
resp = Modbux.Rtu.Master.request(m_pid, {:phr, 80, 1, 102})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:phr, 80, 1, 102}}}
# master
assert resp == :ok
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:hr, 1}] == 102
# Force Multiple Coils (FC=15)
resp = Modbux.Rtu.Master.request(m_pid, {:fc, 80, 1, [0, 1]})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:fc, 80, 1, [0, 1]}}}
# master
assert resp == :ok
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:c, 1}] == 0
assert model[80][{:c, 2}] == 1
# backward
resp = Modbux.Rtu.Master.request(m_pid, {:fc, 80, 1, [1, 0]})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:fc, 80, 1, [1, 0]}}}
# master
assert resp == :ok
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:c, 1}] == 1
assert model[80][{:c, 2}] == 0
# Preset Multiple Registers (FC=16)
resp = Modbux.Rtu.Master.request(m_pid, {:phr, 80, 1, [0, 1]})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:phr, 80, 1, [0, 1]}}}
# master
assert resp == :ok
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:hr, 1}] == 0
assert model[80][{:hr, 2}] == 1
# backward
resp = Modbux.Rtu.Master.request(m_pid, {:phr, 80, 1, [102, 103]})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:phr, 80, 1, [102, 103]}}}
# master
assert resp == :ok
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:hr, 1}] == 102
assert model[80][{:hr, 2}] == 103
# Return exception for invalid address
resp = Modbux.Rtu.Master.request(m_pid, {:phr, 80, 2, [102, 103]})
# slave
assert_receive {:modbus_rtu, {:slave_error, {:phr, 80, 2, 'fg'}, :eaddr}}
# master
assert resp == {:error, :eaddr}
model = Modbux.Rtu.Slave.get_db(s_pid)
assert model[80][{:hr, 1}] == 102
assert model[80][{:hr, 2}] == 103
# Return CRC error
# bad crc
assert Modbux.Rtu.Slave.raw_write(s_pid, <<80, 4, 2, 0, 1, 133, 61>>)
resp = Modbux.Rtu.Master.read(m_pid)
assert resp == {:error, :ecrc}
Modbux.Rtu.Master.configure(m_pid, active: true)
# Active mode.
# Read Coil Status (FC=01)
resp = Modbux.Rtu.Master.request(m_pid, {:rc, 80, 1, 1})
# slave
assert_receive {:modbus_rtu, {:slave_request, {:rc, 80, 1, 1}}}
# master
assert resp == :ok
assert_receive {:modbus_rtu, {:slave_response, {:rc, 80, 1, 1}, [1]}}
end
end