defmodule HL7v2.Segment.SCD do
@moduledoc """
Anti-Microbial Cycle Data (SCD) segment -- HL7v2 v2.5.1.
Contains anti-microbial cycle data for sterilization.
36 fields per HL7 v2.5.1 specification. Fields 1-20 are typed,
fields 21-36 use :raw.
"""
use HL7v2.Segment,
id: "SCD",
fields: [
{1, :cycle_start_time, HL7v2.Type.TS, :o, 1},
{2, :cycle_count, HL7v2.Type.NM, :o, 1},
{3, :temp_max, HL7v2.Type.CQ, :o, 1},
{4, :temp_min, HL7v2.Type.CQ, :o, 1},
{5, :load_number, HL7v2.Type.NM, :o, 1},
{6, :condition_time, HL7v2.Type.CQ, :o, 1},
{7, :sterilize_time, HL7v2.Type.CQ, :o, 1},
{8, :exhaust_time, HL7v2.Type.CQ, :o, 1},
{9, :total_cycle_time, HL7v2.Type.CQ, :o, 1},
{10, :device_status, HL7v2.Type.CWE, :o, 1},
{11, :cycle_start_date_time, HL7v2.Type.TS, :o, 1},
{12, :dry_time, HL7v2.Type.CQ, :o, 1},
{13, :leak_rate, HL7v2.Type.CQ, :o, 1},
{14, :control_temperature, HL7v2.Type.CQ, :o, 1},
{15, :sterilizer_temperature, HL7v2.Type.CQ, :o, 1},
{16, :cycle_complete_time, HL7v2.Type.TS, :o, 1},
{17, :under_temperature, HL7v2.Type.CQ, :o, 1},
{18, :over_temperature, HL7v2.Type.CQ, :o, 1},
{19, :abort_cycle, HL7v2.Type.CNE, :o, 1},
{20, :alarm, HL7v2.Type.CNE, :o, 1},
{21, :field_21, :raw, :o, 1},
{22, :field_22, :raw, :o, 1},
{23, :field_23, :raw, :o, 1},
{24, :field_24, :raw, :o, 1},
{25, :field_25, :raw, :o, 1},
{26, :field_26, :raw, :o, 1},
{27, :field_27, :raw, :o, 1},
{28, :field_28, :raw, :o, 1},
{29, :field_29, :raw, :o, 1},
{30, :field_30, :raw, :o, 1},
{31, :field_31, :raw, :o, 1},
{32, :field_32, :raw, :o, 1},
{33, :field_33, :raw, :o, 1},
{34, :field_34, :raw, :o, 1},
{35, :field_35, :raw, :o, 1},
{36, :field_36, :raw, :o, 1}
]
end