%%% @doc Common Test suite for Erlang-native asyncio event loop.
%%%
%%% Tests the enif_select-based event loop implementation that provides
%%% sub-millisecond latency for asyncio operations.
-module(py_event_loop_SUITE).
-include_lib("common_test/include/ct.hrl").
-export([
all/0,
init_per_suite/1,
end_per_suite/1,
init_per_testcase/2,
end_per_testcase/2
]).
-export([
test_event_loop_create_destroy/1,
test_event_loop_set_worker/1,
test_add_remove_reader/1,
test_add_remove_writer/1,
test_call_later_basic/1,
test_call_later_cancel/1,
test_multiple_timers/1,
test_fd_read_callback/1,
test_poll_events_timeout/1,
test_concurrent_fd_and_timer/1,
test_event_loop_wakeup/1,
test_get_pending_clears_queue/1,
%% TCP tests
test_tcp_listener_create/1,
test_tcp_connect_accept/1,
test_tcp_read_write_callback/1,
test_tcp_echo/1,
%% Lifecycle tests
test_cancel_reader_keeps_fd_open/1,
test_cancel_writer_keeps_fd_open/1,
test_double_close_is_safe/1,
test_cancel_then_reselect/1
]).
all() ->
[
test_event_loop_create_destroy,
test_event_loop_set_worker,
test_add_remove_reader,
test_add_remove_writer,
test_call_later_basic,
test_call_later_cancel,
test_multiple_timers,
test_fd_read_callback,
test_poll_events_timeout,
test_concurrent_fd_and_timer,
test_event_loop_wakeup,
test_get_pending_clears_queue,
%% TCP tests
test_tcp_listener_create,
test_tcp_connect_accept,
test_tcp_read_write_callback,
test_tcp_echo,
%% Lifecycle tests
test_cancel_reader_keeps_fd_open,
test_cancel_writer_keeps_fd_open,
test_double_close_is_safe,
test_cancel_then_reselect
].
init_per_suite(Config) ->
case application:ensure_all_started(erlang_python) of
{ok, _} ->
{ok, _} = py:start_contexts(),
%% Wait for event loop to be fully initialized
%% This is important for free-threaded Python where initialization
%% can race with test execution
case wait_for_event_loop(5000) of
ok ->
Config;
{error, Reason} ->
ct:fail({event_loop_not_ready, Reason})
end;
{error, {App, Reason}} ->
ct:fail({failed_to_start, App, Reason})
end.
%% Wait for the event loop to be fully initialized
wait_for_event_loop(Timeout) when Timeout =< 0 ->
{error, timeout};
wait_for_event_loop(Timeout) ->
case py_event_loop:get_loop() of
{ok, LoopRef} when is_reference(LoopRef) ->
%% Verify the event loop is actually functional by checking
%% we can create and immediately cancel a timer
case py_nif:event_loop_new() of
{ok, TestLoop} ->
py_nif:event_loop_destroy(TestLoop),
ok;
_ ->
timer:sleep(100),
wait_for_event_loop(Timeout - 100)
end;
_ ->
timer:sleep(100),
wait_for_event_loop(Timeout - 100)
end.
end_per_suite(_Config) ->
ok = application:stop(erlang_python),
ok.
init_per_testcase(_TestCase, Config) ->
Config.
end_per_testcase(_TestCase, _Config) ->
ok.
%% ============================================================================
%% Event Loop Lifecycle Tests
%% ============================================================================
test_event_loop_create_destroy(_Config) ->
%% Create event loop
{ok, LoopRef} = py_nif:event_loop_new(),
true = is_reference(LoopRef),
%% Destroy it
ok = py_nif:event_loop_destroy(LoopRef),
ok.
test_event_loop_set_worker(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
%% Start a worker process
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
true = is_pid(WorkerPid),
%% Set worker
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Cleanup
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
%% ============================================================================
%% File Descriptor Monitoring Tests (using pipes - they work with enif_select)
%% ============================================================================
test_add_remove_reader(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create a pipe for testing (pipes work properly with enif_select)
{ok, {ReadFd, WriteFd}} = py_nif:create_test_pipe(),
%% Add reader
CallbackId = 1,
{ok, FdRef} = py_nif:add_reader(LoopRef, ReadFd, CallbackId),
%% Remove reader (pass FdRef, not Fd)
ok = py_nif:remove_reader(LoopRef, FdRef),
%% Cleanup
py_nif:close_test_fd(ReadFd),
py_nif:close_test_fd(WriteFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_add_remove_writer(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
{ok, {ReadFd, WriteFd}} = py_nif:create_test_pipe(),
%% Writer monitors the write end
{ok, FdRef} = py_nif:add_writer(LoopRef, WriteFd, 1),
%% Remove writer (pass FdRef, not Fd)
ok = py_nif:remove_writer(LoopRef, FdRef),
py_nif:close_test_fd(ReadFd),
py_nif:close_test_fd(WriteFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_fd_read_callback(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create pipe - read end for monitoring, write end for triggering
{ok, {ReadFd, WriteFd}} = py_nif:create_test_pipe(),
%% Register reader callback on the read end
CallbackId = 42,
{ok, FdRef} = py_nif:add_reader(LoopRef, ReadFd, CallbackId),
%% Write data to the write end to trigger read readiness on read end
ok = py_nif:write_test_fd(WriteFd, <<"hello">>),
%% Wait for callback dispatch (worker receives {select, ...})
timer:sleep(100),
%% Get pending events
Pending = py_nif:get_pending(LoopRef),
%% Should have received the read callback
HasReadCallback = lists:any(
fun({CId, Type}) -> CId == CallbackId andalso Type == read end,
Pending
),
true = HasReadCallback,
%% Cleanup - remove reader before closing fd
ok = py_nif:remove_reader(LoopRef, FdRef),
py_nif:close_test_fd(ReadFd),
py_nif:close_test_fd(WriteFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
%% ============================================================================
%% Timer Tests
%% ============================================================================
test_call_later_basic(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
CallbackId = 100,
DelayMs = 50,
T1 = erlang:monotonic_time(millisecond),
{ok, _TimerRef} = py_nif:call_later(LoopRef, DelayMs, CallbackId),
%% Wait for timer to fire
timer:sleep(DelayMs + 50),
T2 = erlang:monotonic_time(millisecond),
%% Get pending events
Pending = py_nif:get_pending(LoopRef),
%% Verify callback was triggered
HasTimerCallback = lists:any(
fun({CId, Type}) -> CId == CallbackId andalso Type == timer end,
Pending
),
true = HasTimerCallback,
%% Verify timing accuracy (within tolerance)
Elapsed = T2 - T1,
true = Elapsed >= DelayMs,
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_call_later_cancel(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
CallbackId = 101,
{ok, TimerRef} = py_nif:call_later(LoopRef, 200, CallbackId),
%% Cancel before it fires
ok = py_nif:cancel_timer(LoopRef, TimerRef),
%% Wait past the scheduled time
timer:sleep(300),
%% Verify callback was NOT triggered
Pending = py_nif:get_pending(LoopRef),
HasTimerCallback = lists:any(
fun({CId, Type}) -> CId == CallbackId andalso Type == timer end,
Pending
),
false = HasTimerCallback,
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_multiple_timers(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create timers with different delays
%% Use larger delays for CI reliability (especially on free-threaded Python)
{ok, _} = py_nif:call_later(LoopRef, 20, 1),
{ok, _} = py_nif:call_later(LoopRef, 50, 2),
{ok, _} = py_nif:call_later(LoopRef, 80, 3),
%% Wait for all with margin
timer:sleep(200),
Pending = py_nif:get_pending(LoopRef),
%% All three should have fired
CallbackIds = [CId || {CId, timer} <- Pending],
true = lists:member(1, CallbackIds),
true = lists:member(2, CallbackIds),
true = lists:member(3, CallbackIds),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
%% ============================================================================
%% Poll Events Tests
%% ============================================================================
test_poll_events_timeout(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Poll with short timeout, no events
T1 = erlang:monotonic_time(millisecond),
{ok, NumEvents} = py_nif:poll_events(LoopRef, 50),
T2 = erlang:monotonic_time(millisecond),
%% Should have 0 events and taken ~50ms
0 = NumEvents,
Elapsed = T2 - T1,
true = Elapsed >= 40, %% Allow some tolerance
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_event_loop_wakeup(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Spawn a process to wait
Self = self(),
spawn(fun() ->
T1 = erlang:monotonic_time(millisecond),
{ok, _} = py_nif:poll_events(LoopRef, 5000),
T2 = erlang:monotonic_time(millisecond),
Self ! {poll_done, T2 - T1}
end),
%% Give it time to start waiting
timer:sleep(50),
%% Wake it up
ok = py_nif:event_loop_wakeup(LoopRef),
%% Should receive quickly (not 5 seconds)
receive
{poll_done, Elapsed} ->
true = Elapsed < 1000 %% Should be much less than 5000ms
after 2000 ->
ct:fail(poll_not_woken_up)
end,
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_get_pending_clears_queue(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create a timer that fires quickly
%% Use 20ms minimum for CI reliability
{ok, _} = py_nif:call_later(LoopRef, 20, 999),
timer:sleep(100),
%% First get_pending should return the event
Pending1 = py_nif:get_pending(LoopRef),
true = length(Pending1) > 0,
%% Second get_pending should return empty (queue was cleared)
Pending2 = py_nif:get_pending(LoopRef),
0 = length(Pending2),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_concurrent_fd_and_timer(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Set up pipe and timer
{ok, {ReadFd, WriteFd}} = py_nif:create_test_pipe(),
FdCallbackId = 1,
TimerCallbackId = 2,
%% Keep references to prevent GC
{ok, FdRef} = py_nif:add_reader(LoopRef, ReadFd, FdCallbackId),
{ok, TimerRef} = py_nif:call_later(LoopRef, 50, TimerCallbackId),
%% Trigger fd ready by writing to pipe
ok = py_nif:write_test_fd(WriteFd, <<"data">>),
%% Wait for both - use longer timeout for reliability
timer:sleep(200),
Pending = py_nif:get_pending(LoopRef),
%% Should have both callbacks
HasFdCallback = lists:any(
fun({CId, Type}) -> CId == FdCallbackId andalso Type == read end,
Pending
),
HasTimerCallback = lists:any(
fun({CId, Type}) -> CId == TimerCallbackId andalso Type == timer end,
Pending
),
%% Keep refs alive until here
_ = TimerRef,
true = HasFdCallback,
true = HasTimerCallback,
%% Cleanup - remove reader before closing fd
ok = py_nif:remove_reader(LoopRef, FdRef),
py_nif:close_test_fd(ReadFd),
py_nif:close_test_fd(WriteFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
%% ============================================================================
%% TCP Socket Tests
%% ============================================================================
test_tcp_listener_create(_Config) ->
%% Create a TCP listener on an ephemeral port
{ok, {ListenFd, Port}} = py_nif:create_test_tcp_listener(0),
true = is_integer(ListenFd),
true = ListenFd > 0,
true = is_integer(Port),
true = Port > 0,
%% Cleanup
py_nif:close_test_fd(ListenFd),
ok.
test_tcp_connect_accept(_Config) ->
%% Create listener
{ok, {ListenFd, Port}} = py_nif:create_test_tcp_listener(0),
%% Connect client
{ok, ClientFd} = py_nif:connect_test_tcp(<<"127.0.0.1">>, Port),
true = is_integer(ClientFd),
%% Give connection time to complete (non-blocking connect)
timer:sleep(50),
%% Accept on server side
{ok, ServerFd} = py_nif:accept_test_tcp(ListenFd),
true = is_integer(ServerFd),
%% Cleanup
py_nif:close_test_fd(ServerFd),
py_nif:close_test_fd(ClientFd),
py_nif:close_test_fd(ListenFd),
ok.
test_tcp_read_write_callback(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create listener and connect
{ok, {ListenFd, Port}} = py_nif:create_test_tcp_listener(0),
{ok, ClientFd} = py_nif:connect_test_tcp(<<"127.0.0.1">>, Port),
timer:sleep(50),
{ok, ServerFd} = py_nif:accept_test_tcp(ListenFd),
%% Register server fd for read monitoring
ReadCallbackId = 100,
{ok, FdRef} = py_nif:add_reader(LoopRef, ServerFd, ReadCallbackId),
%% Write data from client
ok = py_nif:write_test_fd(ClientFd, <<"hello tcp">>),
%% Wait for callback dispatch
timer:sleep(100),
%% Get pending events
Pending = py_nif:get_pending(LoopRef),
%% Should have received the read callback
HasReadCallback = lists:any(
fun({CId, Type}) -> CId == ReadCallbackId andalso Type == read end,
Pending
),
true = HasReadCallback,
%% Cleanup - remove reader before closing fds
ok = py_nif:remove_reader(LoopRef, FdRef),
py_nif:close_test_fd(ServerFd),
py_nif:close_test_fd(ClientFd),
py_nif:close_test_fd(ListenFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_tcp_echo(_Config) ->
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create listener and connect
{ok, {ListenFd, Port}} = py_nif:create_test_tcp_listener(0),
{ok, ClientFd} = py_nif:connect_test_tcp(<<"127.0.0.1">>, Port),
timer:sleep(50),
{ok, ServerFd} = py_nif:accept_test_tcp(ListenFd),
%% Register both for read monitoring
ClientReadId = 200,
ServerReadId = 201,
{ok, ServerFdRef} = py_nif:add_reader(LoopRef, ServerFd, ServerReadId),
{ok, ClientFdRef} = py_nif:add_reader(LoopRef, ClientFd, ClientReadId),
%% Client sends data
TestData = <<"echo test data">>,
ok = py_nif:write_test_fd(ClientFd, TestData),
%% Wait for server to receive
timer:sleep(100),
%% Server reads and echoes back
{ok, ReceivedData} = py_nif:read_test_fd(ServerFd, 1024),
ok = py_nif:write_test_fd(ServerFd, ReceivedData),
%% Wait for client to receive echo
timer:sleep(100),
%% Client reads echo
{ok, EchoData} = py_nif:read_test_fd(ClientFd, 1024),
%% Verify echo matches original
TestData = EchoData,
%% Verify we got the callbacks
Pending = py_nif:get_pending(LoopRef),
HasServerCallback = lists:any(
fun({CId, Type}) -> CId == ServerReadId andalso Type == read end,
Pending
),
HasClientCallback = lists:any(
fun({CId, Type}) -> CId == ClientReadId andalso Type == read end,
Pending
),
%% At least server callback should have fired
true = HasServerCallback orelse HasClientCallback,
%% Cleanup - remove readers before closing fds
ok = py_nif:remove_reader(LoopRef, ServerFdRef),
ok = py_nif:remove_reader(LoopRef, ClientFdRef),
py_nif:close_test_fd(ServerFd),
py_nif:close_test_fd(ClientFd),
py_nif:close_test_fd(ListenFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
%% ============================================================================
%% FD Lifecycle Tests
%% ============================================================================
test_cancel_reader_keeps_fd_open(_Config) ->
%% Test that stop_reader stops monitoring but keeps FD open
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create a pipe
{ok, {ReadFd, WriteFd}} = py_nif:create_test_pipe(),
%% Add reader
CallbackId = 100,
{ok, FdRef} = py_nif:add_reader(LoopRef, ReadFd, CallbackId),
%% Stop reader (should NOT close FD) - using new API
ok = py_nif:stop_reader(FdRef),
%% Write to trigger readiness (but no callback since stopped)
ok = py_nif:write_test_fd(WriteFd, <<"test">>),
timer:sleep(50),
%% FD should still be readable since it wasn't closed
{ok, Data} = py_nif:read_test_fd(ReadFd, 1024),
<<"test">> = Data,
%% Verify no callback was dispatched
Pending = py_nif:get_pending(LoopRef),
HasCallback = lists:any(
fun({CId, _Type}) -> CId == CallbackId end,
Pending
),
false = HasCallback,
%% Cleanup - use close_fd since we stopped (remove_reader won't work)
ok = py_nif:close_fd(FdRef),
py_nif:close_test_fd(WriteFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_cancel_writer_keeps_fd_open(_Config) ->
%% Test that stop_writer stops monitoring but keeps FD open
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create a pipe
{ok, {ReadFd, WriteFd}} = py_nif:create_test_pipe(),
%% Add writer
CallbackId = 200,
{ok, FdRef} = py_nif:add_writer(LoopRef, WriteFd, CallbackId),
%% Stop writer (should NOT close FD) - using new API
ok = py_nif:stop_writer(FdRef),
%% FD should still be writable since it wasn't closed
ok = py_nif:write_test_fd(WriteFd, <<"test">>),
%% Verify we can read what was written
{ok, Data} = py_nif:read_test_fd(ReadFd, 1024),
<<"test">> = Data,
%% Cleanup
ok = py_nif:close_fd(FdRef),
py_nif:close_test_fd(ReadFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_double_close_is_safe(_Config) ->
%% Test that calling close_fd twice is idempotent (no crash)
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create a pipe
{ok, {ReadFd, _WriteFd}} = py_nif:create_test_pipe(),
%% Add reader
{ok, FdRef} = py_nif:add_reader(LoopRef, ReadFd, 300),
%% Close once
ok = py_nif:close_fd(FdRef),
%% Close again - should be safe (idempotent)
ok = py_nif:close_fd(FdRef),
%% Also test remove_reader after close is safe
ok = py_nif:remove_reader(LoopRef, FdRef),
%% Note: WriteFd is owned by us and should still work
%% But we won't test that since the pipe's read end is closed
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.
test_cancel_then_reselect(_Config) ->
%% Test that we can stop and then start (resume) monitoring
{ok, LoopRef} = py_nif:event_loop_new(),
{ok, WorkerPid} = py_event_worker:start_link(<<"test">>, LoopRef),
ok = py_nif:event_loop_set_worker(LoopRef, WorkerPid),
%% Create a pipe
{ok, {ReadFd, WriteFd}} = py_nif:create_test_pipe(),
%% Add reader
CallbackId = 400,
{ok, FdRef} = py_nif:add_reader(LoopRef, ReadFd, CallbackId),
%% Stop reader - using new API
ok = py_nif:stop_reader(FdRef),
%% Re-start using start_reader - using new API
ok = py_nif:start_reader(FdRef),
%% Now write to trigger the callback
ok = py_nif:write_test_fd(WriteFd, <<"hello">>),
timer:sleep(100),
%% Should have received the callback since we re-started
Pending = py_nif:get_pending(LoopRef),
HasCallback = lists:any(
fun({CId, Type}) -> CId == CallbackId andalso Type == read end,
Pending
),
true = HasCallback,
%% Cleanup
ok = py_nif:remove_reader(LoopRef, FdRef),
py_nif:close_test_fd(ReadFd),
py_nif:close_test_fd(WriteFd),
py_event_worker:stop(WorkerPid),
py_nif:event_loop_destroy(LoopRef),
ok.