defmodule BMP280.BME280SensorTest do
use ExUnit.Case
alias BMP280.BME280Sensor
doctest BMP280.BME280Sensor
@bme280_calibration1 %{
type: :bme280,
dig_h1: 75,
dig_h2: 338,
dig_h3: 0,
dig_h4: 370,
dig_h5: 60,
dig_h6: 30,
dig_p1: 36_635,
dig_p2: -10_696,
dig_p3: 3024,
dig_p4: 11_092,
dig_p5: -241,
dig_p6: -7,
dig_p7: 12_300,
dig_p8: -12_000,
dig_p9: 5000,
dig_t1: 28_189,
dig_t2: 26_285,
dig_t3: 50
}
@bme280_calibration2 %{
type: :bme280,
dig_h1: 75,
dig_h2: 394,
dig_h3: 0,
dig_h4: 242,
dig_h5: 56,
dig_h6: 30,
dig_p1: 37_189,
dig_p2: -10_580,
dig_p3: 3024,
dig_p4: 8137,
dig_p5: -87,
dig_p6: -7,
dig_p7: 9900,
dig_p8: -10_230,
dig_p9: 4285,
dig_t1: 28_297,
dig_t2: 26_729,
dig_t3: 50
}
test "bme280 1 calculations" do
raw_samples = <<69, 89, 64, 130, 243, 0, 137, 109>>
state = %{calibration: @bme280_calibration1, sea_level_pa: 100_000}
measurement = BME280Sensor.measurement_from_raw_samples(raw_samples, state)
assert_in_delta 26.7460, measurement.temperature_c, 0.0001
assert_in_delta 100_391.49, measurement.pressure_pa, 0.01
assert_in_delta 59.2, measurement.humidity_rh, 0.1
assert_in_delta 18.1, measurement.dew_point_c, 0.1
end
test "bme280 2 calculations" do
raw_samples = <<77, 75, 16, 126, 15, 128, 102, 158>>
state = %{calibration: @bme280_calibration2, sea_level_pa: 100_000}
measurement = BME280Sensor.measurement_from_raw_samples(raw_samples, state)
assert_in_delta 20.2649, measurement.temperature_c, 0.0001
assert_in_delta 100_278.40, measurement.pressure_pa, 0.01
assert_in_delta 64.4, measurement.humidity_rh, 0.1
assert_in_delta 13.3, measurement.dew_point_c, 0.1
end
end