%% Copyright (c) 2014 Basho Technologies, Inc. All Rights Reserved.
%%
%% This Source Code Form is subject to the terms of the Mozilla Public
%% License, v. 2.0. If a copy of the MPL was not distributed with this
%% file, You can obtain one at http://mozilla.org/MPL/2.0/.
%%
%% -------------------------------------------------------------------
%% @doc Interface library for managing probes.<br/>
%%
%% This library contains the main API for accessing all probes
%% executing in exometer.
%%
%% All exported functions in the `exomter_probe' module are invoked
%% by the `exometer' module; a developer will not have to call
%% `exometer_probe' functions directly.
%%
%% A probe is an implementation of the `exometer_probe' behavior
%% which runs in its own process in order to collect data to be
%% handled and reported by exometer. The implementation will be
%% invoked through the `exomoeter_probe' module, which, as stated
%% above, in its turn is invoked by the `exometer' module.
%%
%% A custom exometer probe is invoked by mapping a type to the module
%% name of the custom exometer probe module. All metrics created with the
%% given type will trigger the invocation of the new probe module. See
%% {@section Configuring type - entry maps} for details on how to setup
%% such maps.
%%
%% If the data can be collected at a high speed, and without
%% blocking, an `exometer_entry' implementation can be used instead
%% to do the gathering in-process.
%%
%% A probe is created throgh the `exomter_probe:new/3' call, which in
%% its turn is called by `exometer:new/3'. During probe creation, a
%% new process is spawned to handle the probe and call its
%% implementation. While the created process is not a gen_server, it
%% behaves similarly and provides a state to all implementation
%% calls.
%%
%% Once running, the probe collects data from a subsystem, such as
%% `/proc', `sysfs', and `netlink', through timer-based calls to
%% `probe_sample/1' or explicit calls to `probe_update/2'.
%%
%% A probe implementation can support any number of data points,
%% where each data point is a specifric sample from the probe. For
%% example, a probe that measures network traffic would have
%% `rx_packets', `tx_packets', `errors', `dropped', and other data
%% points reported by `ifconfig(8)' and `ip(8)'.
%%
%% Values are retrieved from the probe through the `probe_get_value/2'
%% call, which specifies the data points to be returned. The probe is
%% expected to gather the given data points and return them to the
%% caller.
%%
%% == The probe callback interface ==
%%
%% The following functions are to be implemented and exported by a probe
%% implementation.
%%
%% === behaviour/0 ===
%%
%% The `behaviour/0' function for an entry implementation should return
%% the atom `probe'. This function will be involved by the
%% exometer system in order to determine if a callback is
%% an entry or a probe.
%%
%% === probe_init/3 ===
%% The `probe_init/3' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_init(Name, Type, Options)</pre>
%%
%% The implementation shall initiate the probe, create the
%% necessary state, and return it for furure access
%% through `probe_update/2', `probe_sample/1' and `get_value/2' calls.
%%
%% The arguments are as follows:
%%
%% + `Name'
%% Specifies the name of the metric to be created as a list of atoms.
%%
%% + `Type'
%% Specifies the type provided to the `exometer:new/3' call (before it
%% was translated by the type - exometer probe map). It can be used if several
%% different types are mapped to the same probe module.
%%
%% + `Options'
%% Specifies an option list that contains additional setup directives to
%% the probe. The actual options to support are a combination of the
%% standard options, described below, and probe specific options
%% processed by `probe_init/3'.
%%
%% Standard options are processed directly by `new/3', before
%% `probe_init/3' is calledm and are as follows:
%%
%% + `{priority, P}'
%% Will be forwarded by the probe's process to `erlang:process_flag/2'.
%%
%% + `{min_heap_size, S}'
%% Will be forwarded by the probe's process to `erlang:process_flag/2'.
%%
%% + `{min_bin_vheap_size, S}'
%% Will be forwarded by the probe's process to `erlang:process_flag/2'.
%%
%% + `{sensitive, true | false}'
%% Will be forwarded by the probe's process to `erlang:process_flag/2'.
%%
%% + `{sample_interval, t}'
%% Specifies the interval, in milliseconds, that `exometer_probe:sample/1'.
%% should be invoked at.
%%
%% The `probe_init/3' implementation is invoked by `exometer:new/3',
%% which calls `exometer_probe:new/3', which invokes the probe
%% implementation..
%%
%% The `probe_init/3' function shall return `{ok, State}' where State
%% is a tuple that will be provided as a the `State' argument to all
%% future probe implementation calls for the metric.
%%
%% If the `sample_interval' option has been specified in `Opts',
%% probe_sample/2' will be invoked immediately after `probe_init/2'
%% returns to retrieve a first sample. After that, `probe_sample/2'
%% will repeatedly will be called by the probe process at the
%% millisecond-specified interval.
%%
%% Should `probe_init/3' return antyhing else but `{ok, State}',
%% invoking `new/3' call will fail.
%%
%%
%% === probe_terminate/1 ===
%% The `probe_terminate/1' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_terminate(State)</pre>
%%
%% The custom probe shall release any resources associated with the
%% given state and return `ok'.
%%
%% The arguments are as follows:
%%
%% + `State'
%% The probe state, originally returned by `probe_init/3' and subsequentially
%% modified by other probe implementation calls.
%%
%%
%% The `probe_terminate/1' implementation is invoked by `exometer:delete/1', which
%% calls `exometer_probe:delete/3', which invokes the probe
%% implementation.
%%
%%
%% === probe_setopts/3 ===
%% The `probe_setopts/2' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_setopts(Entry, Opts, State)</pre>
%%
%% The `probe_setopts/4' implementation is invoked by
%% `exometer:setopts/3', which calls `exometer_probe:setopts/3',
%% which invokes the probe implementation.
%%
%% The implementation of this function shall modify the options of a
%% probe. The `setopts/3' function, which will process standard
%% options before invoking `probe_setopts/4' with the remaining
%% options. See the documentation for `probe_init/3' for details.
%%
%% The arguments are as follows:
%%
%% + `Entry'
%% The (opaque) exometer entry record. See {@link exometer_info} for
%% information on how to inspect the data structure.
%%
%% + `Opts'
%% The probe-specific options to be processed.
%%
%% + `Status'
%% The new status of the entry.
%%
%% + `State'
%% The probe state, originally returned by `probe_init/3' and subsequently
%% modified by other probe implementation calls.
%%
%% This function shall return `{ok, NewState}' where `NewState' is
%% the modified probe state that incorporates the new options.
%%
%%
%% === probe_update/2 ===
%% The `probe_update/2' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_update(Value, State)</pre>
%%
%% Incorporate a new value into the metric maintained by the metric.
%%
%% The arguments are as follows:
%%
%% + `Value'
%% The value to integrate.
%%
%% + `State'
%% The probe state, originally returned by `probe_init/3' and subsequentially
%% modified by other probe implementation calls.
%%
%% This function can be called outside the periodic `probe_sample/1/'
%% call to have the probe process a value given in `Value'.
%%
%% The `probe_update/2' implementation is invoked by `exometer:update/2', which
%% calls `exometer_probe:update/4', which invokes the probe
%% implementation.
%%
%% Once processed, `probe_update/2' shall return `{ok, NewState}',
%% where `NewState' contains the new probe state with the processed
%% value.
%%
%%
%% === probe_get_value/2 ===
%% The `probe_get_value/2' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_get_value(DataPoints, State)</pre>
%%
%% The `probe_get_value/2' implementation shall retrieve the value of
%% one or more data points from the probe.
%%
%% The arguments are as follows:
%%
%% + `DataPoints'
%% List of data point atoms to retrieve values for.
%%
%% + `State'
%% The probe state, originally returned by `probe_init/3' and subsequentially
%% modified by other probe implementation calls.
%%
%% The `probe_get_value/2' implementation is invoked by
%% `exometer:get_value/2', which calls `exometer_probe:get_value/4',
%% which invokes the probe implementation.
%%
%% If `exometer:get_value/2' is invoked with `default' as a single
%% data point, the probe's `probe_get_datapoints/1' function will be
%% called to retrieve all data points supported by the probe
%% implementation. `probe_get_value/2' will then be called with the
%% returned set of data points provided as an argument.
%%
%% This function shall return the value of all data points provided in
%% `DataPoints', given that they are supported.
%%
%% The list in the returned tuple shall have the format:
%%
%% <pre lang="erlang">
%% [{ DP, Val}, ...]</pre>
%%
%% Where `DP' one of the data points in the `DataPoints' argument, and
%% `Val' is the value of that data point.
%%
%% If one of the argument-provided data points are not supported by the probe,
%% the tuple returned for that data point shall be `{ DP, {error, undefined}'.
%%
%% For example, if the provided `DataPoint' argument is set to `[ min,
%% max, xyzzy ]', and only `min' and `max' are supported
%% by the probe, the returned list shall look like below:
%%
%% <pre lang="erlang">
%% [{ min, 0.1265 }, { max, 3338.21 }, { xyzzy, { error, unsupported } ]</pre>
%%
%% The `probe_get_value/2' implementation shall return `{ok, List}',
%% where `List' is the list of data points and their values described
%% above. No new state is returned by this function.
%%
%%
%% === probe_get_datapoints/1 ===
%% The `probe_get_datapoints/1' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_get_datapoints(State)</pre>
%%
%% The `probe_get_datapoints/1' shall return a list with all data points
%% supported by the probe
%%
%% The arguments are as follows:
%%
%% + `State'
%% The probe state, originally returned by `probe_init/3' and subsequentially
%% modified by other probe implementation calls.
%%
%% The `probe_get_datapoints/1' implementation is invoked by
%% `exometer:info/2', which calls `exometer_probe:get_datapoints/3',
%% which invokes the probe implementation.
%%
%% In cases where `exometer:get_value/2' is called with `default' as a
%% single data point, `probe_get_datapoints/1' is also called to
%% retrieve a list of all supported data points, which is then
%% forwarded to `probe_get_value/2'.
%%
%% The implementation of `probe_get_datapoints/1' shall return `{ok, DpList}',
%% where `DpList' is a list of data point atoms supported by the probe.
%%
%%
%% === probe_reset/1 ===
%% The `probe_reset/1' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_reset(State)</pre>
%%
%% The `probe_reset/1' shall reset the state of the probe to its initial state.
%%
%% The arguments are as follows:
%%
%% + `State'
%% The probe state, originally returned by `probe_init/3' and subsequentially
%% modified by other probe implementation calls.
%%
%%
%% The `probe_reset/1' implementation is invoked by
%% `exometer:reset/1', which calls `exometer_probe:reset/3', which
%% invokes the probe implementation.
%%
%% The implementation of `probe_reset/1' shall return `{ok,
%% NewState}', where `NewState' contains the reset state of the probe.
%%
%%
%% === probe_sample/1 ===
%% The `probe_sample/1' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_sample(State)</pre>
%%
%% The `probe_sample/1' implementation shall sample data from the
%% subsystem the probe is integrated with.
%%
%% The arguments are as follows:
%%
%% + `State'
%% The probe state, originally returned by `probe_init/3' and subsequentially
%% modified by other probe implementation calls.
%%
%% When invoked, `probe_sample/1' is expected to interface the
%% sub-system (/proc, /sysfs, etc) monitored by the probe, extract the
%% relevant data from it, and return an updated probe state that
%% incorporates the extracted data.
%%
%% The `probe_sample/1' function is invoked by the probe thread at
%% intervals specified by the `{sample_interval, Intv}' option
%% provided to `exometer_probe:new/3'. If this option is missing, or
%% set to infinity, `probe_sample/1' will never be called.
%%
%% The implementation of `probe_sample/1' shall return `{ok,
%% NewState}', where `NewState' contains the new state of the probe
%% with the sampled data integrated into it.
%%
%%
%% === probe_handle_msg/2 ===
%% The `probe_handle_msg/2' function is invoked as follows:
%%
%% <pre lang="erlang">
%% probe_handle_msg(Msg, State)</pre>
%%
%% The `probe_handle_msg/1' is invoked to process messages received
%% by the probe process.
%%
%% The arguments are as follows:
%%
%% + `State'
%% The probe state, originally returned by `probe_init/3' and subsequentially
%% modified by other probe implementation calls.
%%
%% + `Msg'
%% The probe state, originally returned by `probe_init/3' and subsequentially
%% modified by other probe implementation calls.
%%
%% The implementation of this function will be called by the probe's
%% process when it receives a message that is not recognized by the
%% internal receive loop.
%%
%% The implementation of `probe_handle_msg/2' shall return `{ok,
%% NewState}', where `NewState' contains the new state of the probe
%% that reflects the processed message.
%%
-module(exometer_probe).
-behaviour(exometer_entry).
% exometer_entry callb
-export(
[
behaviour/0,
new/3,
delete/3,
get_datapoints/3,
get_value/3, get_value/4,
update/4,
reset/3,
sample/3,
setopts/3
]).
-include("exometer.hrl").
-record(st, {
name,
type,
module = undefined,
mod_state,
sample_timer,
sample_interval = infinity, %% msec. infinity = disable probe_sample() peridoc calls.
opts = []
}).
-type name() :: exometer:name().
-type options() :: exometer:options().
-type type() :: exometer:type().
-type mod_state() :: any().
-type data_points() :: [atom()].
-type probe_reply() :: ok
| {ok, mod_state()}
| {ok, any(), mod_state()}
| {noreply, mod_state()}
| {error, any()}.
-type probe_noreply() :: ok
| {ok, mod_state()}
| {error, any()}.
-callback behaviour() -> exometer:behaviour().
-callback probe_init(name(), type(), options()) -> probe_noreply().
-callback probe_terminate(mod_state()) -> probe_noreply().
-callback probe_setopts(exometer:entry(), options(), mod_state()) ->
probe_reply().
-callback probe_update(any(), mod_state()) -> probe_noreply().
-callback probe_get_value(data_points(), mod_state()) -> probe_reply().
-callback probe_get_datapoints(mod_state()) -> {ok, data_points()}.
-callback probe_reset(mod_state()) -> probe_noreply().
-callback probe_sample(mod_state()) -> probe_noreply().
-callback probe_handle_msg(any(), mod_state()) -> probe_noreply().
%% FIXME: Invoke this.
-callback probe_code_change(any(), mod_state(), any()) -> {ok, mod_state()}.
new(Name, Type, [{arg, Module}|Opts]) ->
{ ok, exometer_proc:spawn_process(
Name, fun() ->
init(Name, Type, Module, Opts)
end)
};
new(Name, Type, Options) ->
%% Extract the module to use.
{value, { module, Module }, Opts1 } = lists:keytake(module, 1, Options),
new(Name, Type, [{arg, Module} | Opts1]).
%% Should never be called directly for exometer_probe.
behaviour() ->
entry.
delete(_Name, _Type, Pid) when is_pid(Pid) ->
exometer_proc:cast(Pid, delete).
get_value(_Name, _Type, Pid) when is_pid(Pid) ->
exometer_proc:call(Pid, {get_value, default}).
get_value(_Name, _Type, Pid, DataPoints) when is_pid(Pid) ->
exometer_proc:call(Pid, {get_value, DataPoints}).
get_datapoints(_Name, _Type, Pid) when is_pid(Pid) ->
exometer_proc:call(Pid, get_datapoints).
setopts(#exometer_entry{ref = Pid} = E, Opts, Status) when is_pid(Pid) ->
exometer_proc:cast(Pid, {setopts, E, Opts, Status}).
update(_Name, Value, _Type, Pid) when is_pid(Pid) ->
exometer_proc:cast(Pid, {update, Value}).
reset(_Name, _Type, Pid) when is_pid(Pid) ->
exometer_proc:cast(Pid, reset).
sample(_Name, _Type, Pid) when is_pid(Pid) ->
exometer_proc:cast(Pid, sample).
init(Name, Type, Mod, Opts) ->
process_flag(min_heap_size, 40000),
{St0, Opts1} = process_opts(Opts, #st{name = Name,
type = Type,
module = Mod}),
St = St0#st{opts = Opts1},
%% Create a new state for the module
case {Mod:probe_init(Name, Type, St#st.opts),
St#st.sample_interval} of
{ ok, infinity} ->
%% No sample timer to start. Return with undefined mod state
loop(St#st{ mod_state = undefined });
{{ok, ModSt}, infinity} ->
%% No sample timer to start. Return with the mod state returned by probe_init.
loop(St#st{ mod_state = ModSt });
{ok, _} ->
%% Fire up the timer, with undefined mod
loop(sample(St#st{ mod_state = undefined }));
{{ok, ModSt}, _ } ->
%% Fire up the timer.
loop(sample(St#st{ mod_state = ModSt }));
{{error, Reason}, _} ->
%% FIXME: Proper shutdown.
{error, Reason}
end.
loop(St) ->
receive Msg ->
loop(handle_msg(Msg, St))
end.
handle_msg(Msg, St) ->
Module = St#st.module,
case Msg of
{system, From, Req} ->
exometer_proc:handle_system_msg(
Req, From, St, fun(St1) -> loop(St1) end);
{exometer_proc, {From, Ref}, {get_value, default} } ->
{ok, DataPoints} = Module:probe_get_datapoints(St#st.mod_state),
{Reply, NSt} =
process_probe_reply(St, Module:probe_get_value(DataPoints,
St#st.mod_state)),
From ! {Ref, Reply },
NSt;
{exometer_proc, {From, Ref}, {get_value, DataPoints} } ->
{Reply, NSt} =
process_probe_reply(St, Module:probe_get_value(DataPoints,
St#st.mod_state)),
From ! {Ref, Reply },
NSt;
{exometer_proc, {From, Ref}, get_datapoints } ->
{ok, DataPoints} =Module:probe_get_datapoints(St#st.mod_state),
From ! {Ref, DataPoints },
St;
{exometer_proc, { update, Value } } ->
Res = process_probe_noreply(St, Module:probe_update(Value, St#st.mod_state)),
Res;
{exometer_proc, reset } ->
process_probe_noreply(St, Module:probe_reset(St#st.mod_state));
{exometer_proc, sample } ->
process_probe_noreply(St, Module:probe_sample(St#st.mod_state));
{exometer_proc, {From, Ref}, {setopts, Entry, Options}} ->
%% Extract probe-level options (sample_interval)
{NSt, Opts1} = process_opts(Options, St),
{Reply, NSt1} = %% Call module setopts for remainder of opts
process_probe_reply(
NSt, Module:probe_setopts(Entry, Opts1, NSt#st.mod_state)),
From ! {Ref, Reply },
%% Return state with options and any non-duplicate original opts.
NSt1#st {
opts = Opts1 ++
[{K,V} || {K,V} <- St#st.opts, not lists:keymember(K,1,Opts1) ]
};
{timeout, _TRef, {exometer_proc, sample_timer}} ->
sample(St);
{exometer_proc, delete} ->
Module:probe_terminate(St#st.mod_state),
exometer_proc:stop();
{exometer_proc, code_change} ->
Module:probe_terminate(St#st.mod_state),
exometer_proc:stop();
Other ->
process_probe_noreply(St, Module:probe_handle_msg(Other, St#st.mod_state))
end.
process_probe_reply(St, ok) ->
{ok, St};
process_probe_reply(St, {ok, Reply}) ->
{Reply, St};
process_probe_reply(St, {ok, Reply, ModSt}) ->
{Reply, St#st { mod_state = ModSt }} ;
process_probe_reply(St, {noreply, ModSt}) ->
{noreply, St#st { mod_state = ModSt }};
process_probe_reply(St, {error, Reason}) ->
{{error, Reason}, St};
process_probe_reply(St, Err) ->
{{error, { unsupported, Err}}, St}.
process_probe_noreply(St, {ok, ModSt}) ->
St#st{mod_state=ModSt};
process_probe_noreply(St, _) ->
St.
%% ===================================================================
sample(#st{module = Mod, mod_state = ModSt} = St) ->
St1 = restart_timer(sample, St),
process_probe_noreply(St1, Mod:probe_sample(ModSt)).
restart_timer(sample, #st{sample_interval = Int} = St) ->
St#st{sample_timer = start_timer(Int, {exometer_proc, sample_timer})}.
start_timer(infinity, _) ->
undefined;
start_timer(T, Msg) when is_integer(T), T >= 0, T =< 16#FFffFFff ->
erlang:start_timer(T, self(), Msg).
process_opts(Options, #st{} = St) ->
exometer_proc:process_options(Options),
process_opts(Options, St, []).
process_opts([{sample_interval, Val}|T], #st{} = St, Acc) ->
process_opts(T, St#st{ sample_interval = Val }, Acc);
process_opts([Opt|T], St, Acc) ->
process_opts(T, St, [Opt | Acc]);
process_opts([], St, Acc) ->
{St, lists:reverse(Acc)}.